Search

TWO CHANNEL RECEIVER

  DWB100HR-HET receiver is similar to receivers DWP12R and DWP24R and the differences are presented in the below chart:

Equipment type

Power supply

Output Relay Ratings

DWB100HR-HET

10..40 VDC lub 13,5..29 VAC

1A, 120VAC/30VDC

DWP12R

11..17VDC

10A, 277VAC/28VDC

DWP24R

20..35VDC lub 20..27VAC

10A, 277VAC/28VDC

Below you will find the list of common features of receivers DWB100HR-HET, DWP12R and DWP24R :

Easy allocation of hand transmitter buttons to control any receiver output.  for example:

  • Some single button hand transmitters control operation of receiver output one, while other single button transmitters control output two.
  • Any button of multi-button transmitter controls receiver output one, while any other button of the same transmitter controls output two.
  • Two buttons of the same transmitter control one receiver output: one button sets the output on, while other sets the output off.
  • One transmitter button controls two receiver outputs simultaneously, e.g. controlling two equipment units with galvanic separation.

Many receiver outputs operation modes. Receiver outputs can operate in one of many modes:

  • Pressed transmitter button sets receiver output on for programmed time. Next pressed, while in output set on state, prolongs set on time;
  • Pressed transmitter button sets receiver output permanent on. Next pressed, sets output off;
  • Pressed transmitter button sets receiver output on for programmed time. Next pressed, while in output set on state, sets output off;
  • Pressed transmitter button sets receiver output permanent on, or for programmed time. Next pressed, while in output set on state, sets output off.  This mode differs from two earlier described by that, it does not allow two outputs to be set on simultaneously. If output one is on and transmitter button learned to output two is pressed then output one sets off. Next pressed the same button sets output two on. This mode is used for electric motors control;
  • As above, but remote control is performed with the use of single transmitter button only. Subsequent use of the same transmitter button sets on output one, sets the output off, sets on output two, sets the output off. This mode is also used for electric motor control; 
  • Pressed transmitter button sets output on. Subsequent use of the same button does not change output status. The output sets off when other button of the transmitter is pressed. This mode is useful for secure switching on and off remote equipment not visible to operator.
  • Pressed transmitter button sets receiver output on for as long as the button is pressed. Released button sets receiver output off. This remote control mode is frequently used by failed/damaged car transporter operators.
  • Relay output ratings: 1A, 120VAC/30VDC;
  • Power supply: 10..40 VDC or 13,5..29 VAC;
  • The same features as DWP12R / DWP24R;

 

Specyfication: 
specification
Dedicated transmitters